STAAD.PRO AND AI

STAAD.Pro model checks before you run a PEB analysis

Most wrong results come from a model that was wrong before the analysis started. Ten minutes of checking the input saves hours of chasing strange numbers in the output.

16 NOVEMBER 2026 · 7 MIN READ

A PEB model in STAAD.Pro is usually built quickly: a few frames from a template, a run of purlins and girts, bracing, loads and combinations. The analysis then runs in seconds. That speed hides a risk. If the input is wrong, the program still produces a complete, tidy output, and the error only shows up later as a strange design ratio or a reaction that does not make sense.

This checklist is what a checker should go through before pressing run. It is written for portal-frame PEB models but most of it applies to any steel model.

1. Units

  • Confirm the unit system at the top of the input and at every point where it changes. Many models switch between metre and millimetre, or kN and kgf, part way through.
  • Check that section properties for tapered members are entered in the unit active at that point. A web depth of 600 read as metres is an obvious error; a flange thickness entered in centimetres instead of millimetres is not.
  • Check material properties: modulus of elasticity, density and yield strength in consistent units.

2. Geometry and incidences

  • Spans, eave height and roof slope against the general arrangement drawing. Measure at least one frame end to end.
  • Member incidences of every tapered column and rafter. A tapered member’s start depth sits at its first node and its end depth at its second. A column drawn from the knee down to the base, when the base was meant to be the shallow end, puts the deep section in the wrong place.
  • Frame spacing and the location of end-wall frames, which are often different from the main frames.
  • Splits in long members. Rafters are usually divided into segments at splice or taper-change points. Confirm the segments join at shared nodes and that no tiny members were created by accident.

3. Member orientation (beta angles)

  • View the model with section shapes displayed and look along each frame line. Columns and rafters should bend about their strong axis in the plane of the frame.
  • Check the BETA angle on any member whose local axes are not in the default orientation, such as end-wall columns, girts, eave struts and members on sloping planes.
  • Remember that local axes on sloping members follow the member, so a rafter’s strong axis is not the global vertical. Purlins on a sloped roof need their orientation checked against the intended sheet plane.

4. Supports

  • Pinned or fixed bases as per the design basis. Most PEB main frames use pinned bases, but end-wall columns, crane columns or specific client requirements may differ.
  • Supports present at every base, including end-wall and wind columns. A missing support makes the analysis fail or, worse, lets the structure find a strange load path.
  • Any spring or partial support values documented and in the right units.

5. Member releases

  • MEMBER RELEASE on purlins, girts, bracing and secondary beams that are bolted with simple connections.
  • Releases at the correct end (START or END) of the member, which again depends on incidence direction.
  • No mechanism created by releasing both ends of members that the frame depends on for stability, or by releasing the same degree of freedom on every member meeting at a node.

6. Duplicates and connectivity

  • Run the program’s checks for duplicate nodes and duplicate members. Duplicate nodes at the same location leave members unconnected even though the model looks continuous on screen.
  • Look for orphan nodes with nothing attached and members that cross without a shared node where a connection was intended.
  • Confirm bracing is connected to the frame nodes and not to a node a few millimetres away.

7. Loads

  • Directions. In a Y-up model, gravity acts in negative global Y. Check every dead, collateral and live load uses the global direction, not the member’s local axis, unless that was intended.
  • Projected or true length. Roof live load is often defined on plan area, while dead load of the sheeting acts on the slope length. Confirm which one each load uses.
  • Wind. Check the pressure coefficients, the sign convention for pressure and suction, and the internal pressure cases against your wind calculation. Our guide to IS 875 Part 3 wind load for PEB lists the cases a typical building needs.
  • Seismic weight and the load cases that feed it, if a seismic definition is used.
  • Crane loads at the right bracket height and eccentricity, with the moving positions you intend to check.

8. Self-weight

  • A self-weight command, such as SELFWEIGHT Y -1 in a Y-up model, appears once, in the dead load case.
  • Self-weight is not also added as a manual member load.
  • Allowance for connection plates, stiffeners and bolts is handled the way the office has decided, and written in the design basis.

9. Load combinations

  • Every combination in the design basis exists in the model and nothing extra is there.
  • Factors match the code you are designing to.
  • Combinations use the right method for the analysis type. If the model uses PDELTA, strength combinations should normally be REPEAT LOAD cases. Our post on LOAD COMB vs REPEAT LOAD explains why.

10. Analysis and design commands

  • The intended analysis command is present: PERFORM ANALYSIS for a linear run, or the P-Delta command if second-order analysis is required.
  • The load list before the design block selects the strength combinations.
  • Design parameters such as LY, LZ and UNL are assigned to the right members. These control buckling checks and are covered in our post on reading STAAD.Pro steel design output.
  • CHECK CODE and, if used, SELECT are applied to the correct member groups.

After the run: three quick sanity checks

  1. Reactions. Sum the vertical reactions for the dead and live cases and compare with a hand total of the applied load. A mismatch means a load is missing, doubled or reversed.
  2. Deflected shape. Look at each primary case. Gravity cases should sag; wind cases should sway in the expected direction. A frame that moves sideways under symmetric gravity load points to a geometry or support error.
  3. Warnings in the output file. Read every warning about instability, zero stiffness or unconnected nodes. Do not suppress them.

Make the checklist a habit

A printed or shared checklist works better than memory, especially when several people touch the same model. Some offices keep a short sign-off sheet with each item ticked by the modeller and the checker.

Software can take over the repetitive part of this, such as listing members, supports and load cases for the checker to compare against the drawings. Ganithva, for example, opens and edits STAAD.Pro models from plain-language requests, and in Manual mode every proposed change waits for approval. The engineer still reviews the model and signs the design. For the full PEB workflow, see our guide to PEB design in STAAD.Pro and the STAAD.Pro automation page.

Frequently asked questions

Why does a tapered member come out upside down in STAAD.Pro?

The start and end depths of a tapered member follow the member incidence, from the first node to the second. If a rafter or column was drawn in the opposite direction, the deep end lands where the shallow end should be. Check the incidence direction of every tapered member, or view the members with their full section shape displayed.

Does STAAD.Pro include self-weight automatically?

No. Self-weight is added only when the load case contains a self-weight command, usually in the dead load case. Check that it appears once, in the right direction, and that it is not also added by hand as a member load.

What is the quickest check that the model is behaving?

Compare the total vertical reaction in each gravity case with a hand estimate of the applied load, including self-weight. If they do not agree, a load is missing, doubled or acting in the wrong direction. Then look at the deflected shape of each primary case.

Automate. Engineer. Optimize.