GUIDE

PEB design in STAAD.Pro

A good-practice workflow for modelling and checking a pre-engineered building frame with tapered members in STAAD.Pro, and the mistakes that cost the most time.

PUBLISHED · 16 NOVEMBER 2026

1.Plan the model

Before opening the software, write a short design basis: building dimensions, frame type, support conditions, design code (IS 800:2007 or AISC 360), loads and their sources, deflection limits and the bracing scheme. Most rework in PEB models comes from changing one of these halfway through.

Decide early whether to model a single 2D frame or the whole building in 3D. A 2D model of a typical interior frame is quick and enough for primary member design when frames repeat. A 3D model is better when end walls, bracing, cranes, mezzanines or irregular frames interact, and when you want one model for the whole design.

2.Geometry and supports

  • Nodes at the right places. Place nodes at column bases, knees, the ridge, every splice and wherever a point load, purlin or flange brace matters. Splice nodes let each tapered segment be its own member.
  • Centreline geometry. Tapered members change depth, so the centreline is not straight relative to the outer flange. Most designers model the centreline as straight lines between the nodes and accept the small offset; whatever you do, be consistent.
  • Supports. Use pinned supports for pinned bases and fixed supports only when the base plate and foundation are actually designed for moment.
  • Member orientation. Check local axes so the strong axis resists in-plane bending. A rotated member gives plausible but wrong results.

3.Tapered members

STAAD.Pro defines a tapered I-section with the TAPERED property, which takes seven values in this order:

PositionValue
1Depth of section at the start node
2Web thickness
3Depth of section at the end node
4Top flange width
5Top flange thickness
6Bottom flange width
7Bottom flange thickness

The start and end follow the member's incidence, so a rafter drawn ridge-to-knee will have its depths reversed. Check the incidences before assigning, or the deep end of the haunch will sit at the ridge. Depths are overall depths, and the values are in the current length unit.

Columns that are prismatic can use the same property with equal start and end depths. Purlins and girts are not usually modelled in frame design; their loads are applied to the frame directly.

4.Loads

  • Dead load. Self-weight of the frame from the software, plus sheeting, purlins, insulation and any hung loads as uniform member loads.
  • Collateral load. Services, lighting, sprinklers and ducts, as agreed with the client.
  • Live load. Roof live load from IS 875 (Part 2), which depends on roof slope and access.
  • Wind load. Net pressures from IS 875 (Part 3) applied as member loads on columns and rafters, for each direction and each internal pressure case. Our IS 875 Part 3 wind load guide works out these pressures. Calculating them by hand and entering them as member loads keeps every coefficient visible.
  • Seismic load. From IS 1893 (Part 1):2016, using the seismic weight and the response reduction factor for the frame type.
  • Crane loads. Vertical wheel loads with impact, and lateral and longitudinal surge, at the bracket positions.

Check the direction of every wind load. Member loads in global and local directions behave differently on sloping rafters, and a sign error in one case can hide behind a governing case for a long time.

5.Load combinations

Write the strength combinations from your design code and a separate set of serviceability combinations for deflection. The factors differ between IS 800 and AISC 360; see IS 800 vs AISC 360 for PEB.

LOAD COMB adds the results of primary cases after a linear analysis. That is fine for a first-order analysis. If you use P-Delta or another non-linear analysis, results cannot simply be added, so each combination must be formed as its own load case with REPEAT LOAD and analysed. Keep the strength and serviceability combinations clearly numbered so the code check and the deflection check use the right sets.

6.Code checks and parameters

Select the code (IS 800 or AISC 360) and set the design parameters for each member group. The parameters matter as much as the sections:

  • Yield strength for the plate grade used.
  • Effective length factors and lengths for in-plane and out-of-plane buckling.
  • Unbraced lengths of the top and bottom flanges for lateral-torsional buckling. The top flange of a rafter is restrained by purlins; the bottom flange only at flange braces. Under uplift the bottom flange is in compression, so its unbraced length often governs.
  • Deflection parameters so the check measures deflection over the whole rafter span.

Confirm in the documentation of the code module you are using how it treats tapered members, where along the member it checks, and how it classifies slender webs.

7.Deflection and iteration

Check rafter vertical deflection and column sway under the serviceability combinations, against the limits in the design basis. For light PEB frames this often governs.

Then iterate. Change sections where checks fail, and reduce sections where utilisation is low. After every change, analyse again, because the forces in an indeterminate frame depend on the relative stiffness of its members. A design is only finished when the final sections pass on their own final analysis. Done by hand, this loop is where most of the hours go; our PEB optimization guide explains how to run it systematically.

Finally, extract the steel weight for the estimate; the steel take-off guide covers what the analysis model does and does not include.

8.Where Ganithva helps

Ganithva is AI design software for pre-engineered steel buildings that works with STAAD.Pro models. It can open, edit and run your existing models, and it also has its own analysis and design-check engine. It helps with the repetitive parts of the workflow above:

  • Building a frame model with tapered members from a project brief.
  • Working out IS 875 wind and IS 1893 seismic loads and the combinations.
  • Member checks to IS 800:2007 or AISC 360, and tapered-section optimization.
  • DXF elevation and plan drawings, and a steel take-off to Excel.

The engineer approves every change, and the engineer remains responsible for the design; Ganithva does not certify designs.

9.FAQ

How do I define a tapered member in STAAD.Pro?

Use the TAPERED member property. It takes seven values in order: depth at the start node, web thickness, depth at the end node, top flange width, top flange thickness, bottom flange width and bottom flange thickness. The start and end follow the member incidence, so check the direction of each member.

Should I use LOAD COMB or REPEAT LOAD for PEB combinations?

LOAD COMB adds the results of primary load cases after a linear analysis, which is fine for a first-order analysis. If you run a P-Delta or other non-linear analysis, the combination has to be analysed as a load case in its own right, which is what REPEAT LOAD does, because results of a non-linear analysis cannot be added.

How do I check rafter deflection relative to the frame in STAAD.Pro?

Deflection in the code check can be measured relative to a line between two nodes rather than to the member ends. Set the deflection length and the reference nodes so the check covers the whole rafter span, and compare against the limit in your project specification.

Why does my tapered member fail lateral-torsional buckling in STAAD.Pro?

Usually because the unbraced length is left at the member length. Set the unsupported lengths of the top and bottom flanges to match the purlin and flange brace spacing. The compression flange changes between gravity and uplift cases, so both flanges need correct values.

Can Ganithva open my existing STAAD.Pro models?

Yes. Ganithva works with STAAD.Pro models: it can open, edit and run them. It also has its own analysis and design-check engine.

See how Ganithva works alongside STAAD.Pro on the STAAD.Pro automation page, design without a STAAD.Pro installation with the PEB design software, or book a walkthrough.

Automate. Engineer. Optimize.