1.Why take-off accuracy matters

A PEB is priced largely by its steel tonnage. The take-off feeds the quotation, the plate purchase, the fabrication plan and the transport plan, so an error in either direction costs money: too low and the job loses margin, too high and the quote loses the job.

Rolled sections are easy because their weight per metre is tabulated. PEB frames are built up from plates and taper along their length, so there is no table to look up. Their weight has to be calculated from the plate dimensions.

2.The plate weight formula

The weight of any steel plate is its volume times the density of steel:

Weight (kg) = width (m) × thickness (m) × length (m) × 7850 kg/m³

Two shortcuts help with checking:

  • One square metre of 1 mm plate weighs 7.85 kg, so one square metre of 8 mm plate weighs 62.8 kg.
  • Weight per metre of a strip (kg/m) = width (mm) × thickness (mm) × 0.00785. A 200 × 10 mm flange weighs 15.7 kg/m.

3.Weight of a tapered member

A tapered built-up I-section has three plates: the web and two flanges.

Web

The web of a straight-tapered member is a trapezoid. Its area is the average of the two end depths times the length, which is exact for a straight taper, not an approximation:

Web weight = ((dw1 + dw2) / 2) × tw × L × 7850

Here dw1 and dw2 are the clear web depths at each end: overall depth minus the top and bottom flange thicknesses. Using overall depth instead overstates the web slightly.

Flanges

Each flange is a strip of constant width and thickness:

Flange weight = bf × tf × L × 7850, for each flange.

On a tapered member, one flange is sloped relative to the other, so strictly it is a little longer than the member length. For normal PEB tapers the difference is small, but it is worth including for steep tapers.

Plates that are not in the model

End plates at splices and knees, web stiffeners, base plates, cap plates, gussets, purlin cleats and flange brace cleats are usually not modelled. They are calculated from the connection drawings with the same plate formula.

4.Worked example

A rafter segment 9.0 m long tapers from 800 mm overall depth at the knee to 450 mm at the splice. Web 6 mm; both flanges 220 × 10 mm. It has a 240 × 25 × 950 mm end plate at the knee and a 240 × 20 × 600 mm splice plate.

PartCalculationWeight
Clear web depths800 − 20 = 780 mm; 450 − 20 = 430 mm; average 605 mm
Web0.605 × 0.006 × 9.0 × 7850256.5 kg
Two flanges2 × 0.220 × 0.010 × 9.0 × 7850310.9 kg
Member (web + flanges)256.5 + 310.9567.3 kg (63.0 kg/m)
Knee end plate0.240 × 0.025 × 0.950 × 785044.7 kg
Splice end plate0.240 × 0.020 × 0.600 × 785022.6 kg
Total with end plates634.7 kg

Two observations. The flanges weigh more than the web even though the web is far deeper, which is typical and is why flange sizing matters so much in PEB optimization. And the two end plates add about 12% to this segment, so leaving connections out of the take-off is not a small error. Stiffeners and cleats would add a little more.

5.Secondary members and bracing

Cold-formed Z and C purlins and girts are formed from flat strip, so their weight is the developed width of the strip times its thickness times the density. For example, a Z section 200 mm deep with flanges of 60 mm and 65 mm and 20 mm lips, in 2.0 mm material, has a developed width of roughly 365 mm, giving about 0.365 × 0.002 × 7850 ≈ 5.7 kg/m. Supplier tables give exact values allowing for corner radii, and should be used where available.

Count purlin laps: lapped purlins over the frames add length at every support. Add eave struts, sag rods, flange braces, rod or angle bracing with their gussets and turnbuckles, and anchor bolts.

6.Structuring the take-off

CategoryTypical items
Primary framesColumns, rafters, end wall columns and rafters, wind columns
ConnectionsEnd plates, base plates, stiffeners, cap plates, gussets
Secondary membersPurlins, girts, eave struts, laps, cleats
BracingRoof and wall bracing, portal bracing, flange braces, sag rods
MiscellaneousCrane beams, mezzanines, canopies, framed openings, anchor bolts, bolts
Sheeting and accessoriesRoof and wall sheeting (m²), trims, gutters, vents, skylights

Report weights by category and by member mark, with totals per frame line. Keep sheeting in square metres rather than tonnes. Many firms also track weight per square metre of floor area from their own completed jobs; it is a useful sanity check, provided the comparison is with buildings of similar span, eave height, bay spacing, wind speed and crane loading.

7.Common mistakes

  • Using overall depth instead of clear web depth for the web.
  • Counting frames wrongly: end walls usually differ from interior frames.
  • Leaving out connections, purlin laps, or bracing hardware.
  • Taking the analysis model weight as the final weight. Models carry the members, not the details; for what an analysis model includes, see PEB design in STAAD.Pro.
  • Estimating before the design is checked. If the frame changes after the quote, so does the tonnage. The PEB components guide lists everything a complete take-off should cover.

8.FAQ

How do I calculate the weight of a steel plate?

Multiply width × thickness × length in metres to get the volume in cubic metres, then multiply by the density of steel, 7850 kg/m³. A quick check: one square metre of 1 mm plate weighs 7.85 kg.

How do I calculate the weight of a tapered web?

A web that tapers in a straight line is a trapezoid, so its area is the average of the two end web depths times the length. Use the clear web depth (overall depth minus both flange thicknesses), multiply by the web thickness and 7850 kg/m³.

Does STAAD.Pro steel take-off include connections?

The take-off from an analysis model is based on the member properties and lengths in the model, so it does not include end plates, stiffeners, base plates, bolts, purlin cleats or other details that are not modelled. Those have to be added from the connection design or by an allowance agreed for the project.

How is PEB tonnage usually reported?

Most firms report it by category: primary frames, secondary members, bracing, connections and miscellaneous items, with sheeting in square metres. Many also track weight per square metre of floor area, compared with their own past projects of similar span, height and loading.

Ganithva produces a steel take-off to Excel from the designed model, alongside DXF drawings, for the engineer and estimator to review. See PEB design software, PEB optimization for lighter tapered sections, or book a walkthrough.