LOADS AND CODES

IS 800:2026 vs IS 800:2007: clause-by-clause comparison tables

IS 800:2026, the Fourth Revision of the Indian steel code, was published by BIS in October 2026. Every change that moves a design number is set out below in tables, against the 2007 edition, with the effect on PEB and steel frames.

18 NOVEMBER 2026 · 6 MIN READ

Partial safety factors (γm0 = 1.10, γm1 = 1.25), load factors, tension, shear, slenderness limits, deflection limits and the column buckling formula are unchanged. Everything else that matters is in the tables. ε = √(250/fy). Clause numbers are those of the 2026 edition. Values are given in our own words; read the code itself before you design to it. For the American code, see IS 800 vs AISC 360 for PEB.

IS 800:2026 at a glance

Topic IS 800:2007 IS 800:2026 Effect on PEB design
Web in bending (Table 2) 84ε / 105ε / 126ε 70ε / 80ε / 117ε Welded webs drop a class, Md −8 to −15 %
Lateral-torsional buckling αLT 0.21 rolled, 0.49 welded αLT from section shape, fm for moment gradient Welded rafters −1 to −5 % at uniform moment, up to +13 % with gradient
Combined forces One set of interaction factors Factors by section class (Table 18) Minor-axis term up to +67 % for class 3 and 4
Buckling curves Cold-formed tubes curve b Curve c; new curve a0 above fy 420 Cold-formed tube struts −6 to −10 %
Seismic R from IS 1893 R = 1.5 for non-ductile industrial frames About 2.7× the seismic force of an R = 4 frame
Second-order effects λcr mainly for plastic analysis λcr check for every frame (11.7) Amplify or run second-order where λcr is low
Base plate bearing 0.6 fck min(0.3 fck √(A1/A2), 0.9 fck) Larger base plates on slabs and small pedestals
Working stress design Section 11 Withdrawn Limit state only

Section numbers: 2007 to 2026

Subject IS 800:2007 IS 800:2026
General design requirements 3 10
Section classification, Table 2 3.7 10.8
Methods of structural analysis 4 11
Limit state design 5 12
Tension members 6 13
Compression members 7 14
Bending members 8 15
Combined forces 9 16
Connections 10 17
Working stress design 11 Withdrawn
Earthquake 12 18
Fatigue 13 19
Design assisted by testing 14 20
Durability 15 21
Fire resistance 16 22
Sustainable steel construction — 23 (new)
Fabrication and erection 17 24
Plate girders with corrugated web — Annex G (new)

Width-to-thickness limits (Table 2)

Plastic / compact / semi-compact limits.

Element IS 800:2007 IS 800:2026 Change
Web, neutral axis at mid-depth (d/tw) 84ε / 105ε / 126ε 70ε / 80ε / 117ε Tighter, compact −24 %
Web, axial compression (d/tw) — / — / 42ε 27ε / 33ε / 37ε Tighter, new class 1 and 2 limits
Flange outstand, rolled (b/tf) 9.4ε / 10.5ε / 15.7ε 8.7ε / 9.7ε / 13.6ε Tighter
Flange outstand, welded (b/tf) 8.4ε / 9.4ε / 13.6ε 8.7ε / 9.7ε / 13.6ε Slightly looser
Angle, compression due to bending (b/t, d/t) 9.4ε / 10.5ε / 15.7ε 8.7ε / 9.7ε / 14.5ε Tighter
Single angle, axial (b/t, d/t; (b+d)/t) 15.7ε; 25ε 14.5ε; 22.3ε Tighter
Angle leg back-to-back (d/t) 9.4ε / 10.5ε / 15.7ε 8.7ε / 9.7ε / 14.5ε Tighter
Circular hollow, bending (D/t) 42ε² / 52ε² / 146ε² 48ε² / 68ε² / 87ε² Class 1, 2 looser; class 3 much tighter
Circular hollow, axial (D/t) 88ε² 87ε² About the same
Change in the limit, IS 800:2007 → 2026Web in bending, plasticWeb in bending, plastic: 84 → 70 (-17 %)-17 %Web in bending, compactWeb in bending, compact: 105 → 80 (-24 %)-24 %Web in bending, semi-compactWeb in bending, semi-compact: 126 → 117 (-7 %)-7 %Web in axial compression, semi-compactWeb in axial compression, semi-compact: 42 → 37 (-12 %)-12 %Rolled flange outstand, semi-compactRolled flange outstand, semi-compact: 15.7 → 13.6 (-13 %)-13 %Welded flange outstand, compactWelded flange outstand, compact: 9.4 → 9.7 (+3 %)+3 %Angle leg, semi-compactAngle leg, semi-compact: 15.7 → 14.5 (-8 %)-8 %Tube in bending, semi-compactTube in bending, semi-compact: 146 → 87 (-40 %)-40 %Tube in bending, compactTube in bending, compact: 52 → 68 (+31 %)+31 %Tighter: more sections lose a classLooser
Limits in multiples of ε (ε² for tubes). Negative means tighter. Hover a bar for both values.

What it means at fy 345 (ε ≈ 0.85):

Member d/tw or b/tf Class in 2007 Class in 2026 Effect
Welded column or haunch web, bending 68 to 89 Compact Semi-compact Md from Ze, −8 to −15 %
Welded web, bending 100 to 107 Semi-compact Slender Effective section needed
ISHB 300 flange at fy 410 11.8 Semi-compact Slender (limit ≈ 10.6) Effective section needed

Lateral-torsional buckling (15.2.2, Tables 13 and 14)

Item IS 800:2007 IS 800:2026
αLT, welded I, tf ≤ 40 0.49 0.21 √(Zez/Zey) ≤ 0.64
αLT, welded I, tf > 40 0.49 0.25 √(Zez/Zey) ≤ 0.76
αLT, rolled I or H, h/bf > 1.2, tf ≤ 40 0.21 0.12 √(Zez/Zey) ≤ 0.34
αLT, other rolled I or H 0.21 0.16 √(Zez/Zey) ≤ 0.49
αLT, other rolled shapes 0.21 0.76
Moment-gradient factor fm — 1.0 uniform; 1.25 − 0.1ψ − 0.15ψ² linear; 1.05 UDL
Moment cap, simply supported beams 1.2 Ze fy/γm0 1.2 Ze fy/γm0
Moment cap, continuous and frame members 1.2 Ze fy/γm0 (simply supported rule) 1.5 Ze fy/γm0
Moment cap, cantilevers 1.5 Ze fy/γm0 1.2 Ze fy/γm0
Simplified compression-flange method — New (15.2.2.2)

Effect on a typical welded PEB rafter (600 × 200 × 6 × 10, fy 345), against 2007:

Unbraced length Uniform moment (fm 1.0) Linear gradient, ψ = 0 (fm 1.25)
1.5 m −3 % +12 %
3.0 m −5 % +6 %
4.5 m −4 % 0 %
6.0 m and more −3 % to 0 % −1 % to 0 %
Beam buckling strength, IS 800:2026 against 2007 (%)-50+5+101.534.567.5910.512Unbraced length (m)Change (%)1.5 m, moment gradient: +12.0 %2 m, moment gradient: +12.9 %2.5 m, moment gradient: +8.9 %3 m, moment gradient: +5.5 %3.5 m, moment gradient: +3.0 %4 m, moment gradient: +1.3 %4.5 m, moment gradient: +0.3 %5 m, moment gradient: -0.3 %5.5 m, moment gradient: -0.6 %6 m, moment gradient: -0.7 %6.5 m, moment gradient: -0.8 %7 m, moment gradient: -0.7 %7.5 m, moment gradient: -0.6 %8 m, moment gradient: -0.6 %8.5 m, moment gradient: -0.4 %9 m, moment gradient: -0.3 %9.5 m, moment gradient: -0.2 %10 m, moment gradient: -0.1 %10.5 m, moment gradient: +0.0 %11 m, moment gradient: +0.2 %11.5 m, moment gradient: +0.3 %12 m, moment gradient: +0.4 %1.5 m, uniform moment: -2.8 %2 m, uniform moment: -3.6 %2.5 m, uniform moment: -4.2 %3 m, uniform moment: -4.5 %3.5 m, uniform moment: -4.5 %4 m, uniform moment: -4.3 %4.5 m, uniform moment: -4.0 %5 m, uniform moment: -3.5 %5.5 m, uniform moment: -3.1 %6 m, uniform moment: -2.8 %6.5 m, uniform moment: -2.4 %7 m, uniform moment: -2.1 %7.5 m, uniform moment: -1.8 %8 m, uniform moment: -1.5 %8.5 m, uniform moment: -1.3 %9 m, uniform moment: -1.0 %9.5 m, uniform moment: -0.8 %10 m, uniform moment: -0.6 %10.5 m, uniform moment: -0.4 %11 m, uniform moment: -0.3 %11.5 m, uniform moment: -0.1 %12 m, uniform moment: +0.0 %Moment varies linearlyUniform moment
Welded rafter 600 × 200 × 6 × 10, fy 345. Above zero, 2026 gives more capacity than 2007. Hover for values.

Setups that check welded or tapered members with the rolled-section factor of 0.21 will see up to about 20 % less buckling strength.

Combined axial force and bending (16.3.2.2, Table 18)

Item IS 800:2007 IS 800:2026 Members to re-check
Minor-axis factor, semi-compact and slender 0.6 × base factor 1.0 × base factor (+67 %) End-wall columns, eave struts
Minor-axis factor, compact I sections up to 1 + 0.8n up to 1 + 1.4n Biaxial purlins and girts
Members that cannot buckle laterally, tubes, boxes Both equations as usual First equation with a reduced factor on the second moment Tube and box members

In a 2D main frame the minor-axis moment is close to zero, so main frames change little here.

Column buckling curves (Table 10)

Section IS 800:2007 IS 800:2026 Effect
Rolled I and hot-rolled tubes, fy > 420 a a0 (α = 0.13) Better, +6 to +10 %
Cold-formed hollow sections b c −6 % at λ 0.6, −10 % at λ 1.0
Rolled angles c b Better
Channels, tees, monosymmetric Flexural only Torsional and flexural-torsional check added (14.1.2.2) Can govern bracing and chords
Column buckling factor χ, cold-formed hollow sections00.250.50.75100.511.522.5Non-dimensional slenderness λχλ 0: χ 1.000 (curve b)λ 0.1: χ 1.000 (curve b)λ 0.2: χ 1.000 (curve b)λ 0.3: χ 0.964 (curve b)λ 0.4: χ 0.926 (curve b)λ 0.5: χ 0.884 (curve b)λ 0.6: χ 0.837 (curve b)λ 0.7: χ 0.784 (curve b)λ 0.8: χ 0.724 (curve b)λ 0.9: χ 0.661 (curve b)λ 1: χ 0.597 (curve b)λ 1.1: χ 0.535 (curve b)λ 1.2: χ 0.478 (curve b)λ 1.3: χ 0.427 (curve b)λ 1.4: χ 0.382 (curve b)λ 1.5: χ 0.342 (curve b)λ 1.6: χ 0.308 (curve b)λ 1.7: χ 0.278 (curve b)λ 1.8: χ 0.252 (curve b)λ 1.9: χ 0.229 (curve b)λ 2: χ 0.209 (curve b)λ 2.1: χ 0.192 (curve b)λ 2.2: χ 0.176 (curve b)λ 2.3: χ 0.163 (curve b)λ 2.4: χ 0.151 (curve b)λ 2.5: χ 0.140 (curve b)λ 0: χ 1.000 (curve c)λ 0.1: χ 1.000 (curve c)λ 0.2: χ 1.000 (curve c)λ 0.3: χ 0.949 (curve c)λ 0.4: χ 0.897 (curve c)λ 0.5: χ 0.843 (curve c)λ 0.6: χ 0.785 (curve c)λ 0.7: χ 0.725 (curve c)λ 0.8: χ 0.662 (curve c)λ 0.9: χ 0.600 (curve c)λ 1: χ 0.540 (curve c)λ 1.1: χ 0.484 (curve c)λ 1.2: χ 0.434 (curve c)λ 1.3: χ 0.389 (curve c)λ 1.4: χ 0.349 (curve c)λ 1.5: χ 0.315 (curve c)λ 1.6: χ 0.284 (curve c)λ 1.7: χ 0.258 (curve c)λ 1.8: χ 0.235 (curve c)λ 1.9: χ 0.214 (curve c)λ 2: χ 0.196 (curve c)λ 2.1: χ 0.180 (curve c)λ 2.2: χ 0.166 (curve c)λ 2.3: χ 0.154 (curve c)λ 2.4: χ 0.143 (curve c)λ 2.5: χ 0.132 (curve c)2007, curve b2026, curve c
The gap is largest near λ = 1: χ falls from 0.597 to 0.540, about 10 % less axial capacity.

The imperfection factors (a 0.21, b 0.34, c 0.49, d 0.76) and the χ formula are unchanged.

Seismic design (Section 18)

Item IS 800:2007 IS 800:2026
Ordinary moment frame, R From IS 1893 (steel OMRF 3) 4.0
Non-ductile frame, R — 1.5
Frames by zone Ordinary frames restricted in zones IV and V Ordinary frames zone II only; zone III and above special or non-ductile
Single-storey industrial frames, height/span below 1.0, regular Ductile detailing to frame type May be non-ductile: R = 1.5, no ductility rules
Connections of non-ductile frames — Full member capacity, +50 % force in zone V
Design seismic force, relative to an R = 4 frameSpecial moment frame, R 5Special moment frame, R 5: 0.80× the force of an R = 4 frame0.80×Ordinary moment frame, IS 800:2026, R 4Ordinary moment frame, IS 800:2026, R 4: 1.00× the force of an R = 4 frame1.00×Ordinary moment frame, IS 1893, R 3Ordinary moment frame, IS 1893, R 3: 1.33× the force of an R = 4 frame1.33×Non-ductile frame, IS 800:2026, R 1.5Non-ductile frame, IS 800:2026, R 1.5: 2.67× the force of an R = 4 frame2.67×
Seismic force scales with 1/R. Most PEB frames will take the non-ductile route, at R = 1.5.

Tapered PEB frames with slender webs cannot meet the section rules of a moment frame, so most PEB frames will take R = 1.5. In light sheds in low zones wind often still governs; in zones IV and V, and with mezzanines or cranes, seismic governs more often than before.

Second-order effects (11.7.1)

Frame λcr / λp What to do
Clad, cladding stiffness ignored 10 or more First-order analysis
4.6 to 10 Amplify first-order effects (11.7.3)
below 4.6 Second-order analysis
Unclad, or cladding stiffness counted 20 or more First-order analysis
5.75 to 20 Amplify
below 5.75 Second-order analysis
Elastic critical load factor λcr: which analysis to runClad, cladding ignoredClad, cladding ignored: λcr 0 to 4.6: Second-order analysisClad, cladding ignored: λcr 4.6 to 10: Amplify first-orderClad, cladding ignored: λcr 10 to 25: First-order is enough4.610Unclad or cladding countedUnclad or cladding counted: λcr 0 to 5.75: Second-order analysisUnclad or cladding counted: λcr 5.75 to 20: Amplify first-orderUnclad or cladding counted: λcr 20 to 25: First-order is enough5.7520Second orderAmplifyFirst order
Low-pitch portals with tall columns often land between 4 and 10 under full gravity load.

Low-pitch portals with tall columns can have λcr between about 4 and 10 under full gravity load.

Connections and column bases

Item IS 800:2007 IS 800:2026
Bolt shear and bearing Vdsb, Vdpb with kb Unchanged
Bolt tension 0.9 fub An, capped by shank yield Unchanged
Fillet weld, simple check fu/(√3 γmw) Unchanged
Fillet weld, combined stress √(fa² + 3q²) ≤ fu/(√3 γmw) Printed as ≤ fu/γmw; confirm with BIS before using
Base plate bearing on concrete 0.6 fck min(0.3 fck √(A1/A2), 0.9 fck)
Anchor bolts — At least 4; 6 for slab bases carrying earthquake forces
Crane runways, relative rail displacement 10 mm 25 mm
Bearing strength of concrete under a base plate (× fck)00.30.60.9123456789Area ratio A1/A2 (supporting area / loaded area)× fckA1/A2 = 1: 0.60 fck (2007)A1/A2 = 1.5: 0.60 fck (2007)A1/A2 = 2: 0.60 fck (2007)A1/A2 = 2.5: 0.60 fck (2007)A1/A2 = 3: 0.60 fck (2007)A1/A2 = 3.5: 0.60 fck (2007)A1/A2 = 4: 0.60 fck (2007)A1/A2 = 4.5: 0.60 fck (2007)A1/A2 = 5: 0.60 fck (2007)A1/A2 = 5.5: 0.60 fck (2007)A1/A2 = 6: 0.60 fck (2007)A1/A2 = 6.5: 0.60 fck (2007)A1/A2 = 7: 0.60 fck (2007)A1/A2 = 7.5: 0.60 fck (2007)A1/A2 = 8: 0.60 fck (2007)A1/A2 = 8.5: 0.60 fck (2007)A1/A2 = 9: 0.60 fck (2007)A1/A2 = 1: 0.30 fck (2026)A1/A2 = 1.5: 0.37 fck (2026)A1/A2 = 2: 0.42 fck (2026)A1/A2 = 2.5: 0.47 fck (2026)A1/A2 = 3: 0.52 fck (2026)A1/A2 = 3.5: 0.56 fck (2026)A1/A2 = 4: 0.60 fck (2026)A1/A2 = 4.5: 0.64 fck (2026)A1/A2 = 5: 0.67 fck (2026)A1/A2 = 5.5: 0.70 fck (2026)A1/A2 = 6: 0.73 fck (2026)A1/A2 = 6.5: 0.76 fck (2026)A1/A2 = 7: 0.79 fck (2026)A1/A2 = 7.5: 0.82 fck (2026)A1/A2 = 8: 0.85 fck (2026)A1/A2 = 8.5: 0.87 fck (2026)A1/A2 = 9: 0.90 fck (2026)2007: 0.6 fck2026: 0.3 fck √(A1/A2)
On a slab or a pedestal no larger than the plate (A1/A2 = 1), 2026 allows half the 2007 bearing stress. The two meet at A1/A2 = 4.

New and removed clauses

Clause Status What it covers
11.7.1 Changed λcr check now applies to elastic analysis
14.1.2.2 Added Torsional and flexural-torsional buckling
15.2.2, Tables 13 and 14 New Shape-dependent αLT, moment-gradient fm
16.3.2.2, Table 18 New Class-based interaction factors
18.13 New Single-storey industrial buildings, R = 1.5
23 New Sustainable steel construction
Annex G New Plate girders with corrugated web
2007 Section 11 Removed Working stress design

Who is affected

Member or building What changes Rough effect
Welded columns and haunches, d/tw ≈ 68–89 at fy 345 Web compact → semi-compact Md −8 to −15 %
Struts with webs near 37–42ε Stricter web limit in compression Axial −2 to −4 %
Welded rafters, LTB governing New αLT and fm −5 to +13 %
End-wall columns, eave struts, biaxial purlins and girts Larger minor-axis factor Minor-axis term up to +67 %
Cold-formed tube struts and bracing Curve b → c −6 to −10 %
Single-storey industrial frames in seismic zones R = 1.5 About 2.7× an R = 4 design
Tall, low-pitch portals λcr check Amplification or second-order
Column bases on slabs Lower bearing, more anchor bolts Larger plates

Checklist while your software checks to IS 800:2007

Most design software, STAAD.Pro included, still checks members to IS 800:2007 at the time of writing.

Check What to do by hand
Web class List welded webs with d/tw between the old and new limits (about 60 to 107 at fy 345) and re-check them as semi-compact or slender
LTB Re-check welded rafters with the new αLT and fm
Seismic Generate loads with R = 1.5 for single-storey industrial frames; design connections for full member capacity
Second order Compute λcr for each frame; amplify or run P-delta below 10 (clad) or 20 (unclad)
Minor-axis members Re-check end-wall columns, eave struts, purlins and girts
Cold-formed tubes Use curve c
Base plates Re-check bearing and the anchor bolt minimum
Design basis Write the edition into the design basis and the drawing notes

Ganithva checks steel members to IS 800:2026 as well as IS 800:2007: choose the edition on the PEB card, or ask for it in chat. IS 800:2007 stays the default.

Frequently asked questions

What is IS 800:2026?

IS 800:2026 is the Fourth Revision of IS 800, the Indian Standard code of practice for general construction in steel, published by the Bureau of Indian Standards in October 2026. It replaces IS 800:2007 and covers limit state design of steel members, connections, seismic design, fatigue, fire and fabrication.

What are the main changes in IS 800:2026 compared with IS 800:2007?

Tighter width-to-thickness limits for webs, a shape-dependent imperfection factor and a moment-gradient factor for lateral-torsional buckling, class-based interaction factors for combined forces, cold-formed tubes moved to buckling curve c, R = 1.5 for non-ductile industrial frames, a λcr check for second-order effects, a lower concrete bearing limit under base plates, and working stress design withdrawn.

Is working stress design allowed in IS 800:2026?

No. IS 800:2026 withdraws working stress design (Section 11 of the 2007 edition). Design is by the limit state method only.

Do I have to design to IS 800:2026 from now on?

That depends on your contract and on the transition period BIS sets. Many design bases and client specifications still name IS 800:2007, and a job is designed to the edition its design basis names. Check the design basis of each new job, and agree the edition with the client before the first calculation.

Which PEB members are hit hardest by IS 800:2026?

Welded columns and haunches with slender-ish webs, because the web limits in bending are tighter; semi-compact and slender members with minor-axis moment, such as end-wall columns, eave struts and biaxially loaded purlins and girts; cold-formed tube bracing; and, in seismic zones, the whole frame, because single-storey industrial frames take R = 1.5.

Where can I get the IS 800:2026 code?

From the Bureau of Indian Standards (BIS), through its official standards portal. Use a licensed copy: unofficial PDF copies can be incomplete or carry the wrong amendments, and the code is protected by BIS copyright.

Does IS 800:2026 add rules for tapered members?

No. As in the 2007 edition, tapered members have no dedicated provisions. Check the section at enough stations along the member, with the classification, capacity and buckling rules applied to each station.