Partial safety factors (γm0 = 1.10, γm1 = 1.25), load factors, tension, shear, slenderness limits, deflection limits and the column buckling formula are unchanged. Everything else that matters is in the tables. ε = √(250/fy). Clause numbers are those of the 2026 edition. Values are given in our own words; read the code itself before you design to it. For the American code, see IS 800 vs AISC 360 for PEB.
IS 800:2026 at a glance
| Topic | IS 800:2007 | IS 800:2026 | Effect on PEB design |
|---|---|---|---|
| Web in bending (Table 2) | 84ε / 105ε / 126ε | 70ε / 80ε / 117ε | Welded webs drop a class, Md −8 to −15 % |
| Lateral-torsional buckling | αLT 0.21 rolled, 0.49 welded | αLT from section shape, fm for moment gradient | Welded rafters −1 to −5 % at uniform moment, up to +13 % with gradient |
| Combined forces | One set of interaction factors | Factors by section class (Table 18) | Minor-axis term up to +67 % for class 3 and 4 |
| Buckling curves | Cold-formed tubes curve b | Curve c; new curve a0 above fy 420 | Cold-formed tube struts −6 to −10 % |
| Seismic | R from IS 1893 | R = 1.5 for non-ductile industrial frames | About 2.7× the seismic force of an R = 4 frame |
| Second-order effects | λcr mainly for plastic analysis | λcr check for every frame (11.7) | Amplify or run second-order where λcr is low |
| Base plate bearing | 0.6 fck | min(0.3 fck √(A1/A2), 0.9 fck) | Larger base plates on slabs and small pedestals |
| Working stress design | Section 11 | Withdrawn | Limit state only |
Section numbers: 2007 to 2026
| Subject | IS 800:2007 | IS 800:2026 |
|---|---|---|
| General design requirements | 3 | 10 |
| Section classification, Table 2 | 3.7 | 10.8 |
| Methods of structural analysis | 4 | 11 |
| Limit state design | 5 | 12 |
| Tension members | 6 | 13 |
| Compression members | 7 | 14 |
| Bending members | 8 | 15 |
| Combined forces | 9 | 16 |
| Connections | 10 | 17 |
| Working stress design | 11 | Withdrawn |
| Earthquake | 12 | 18 |
| Fatigue | 13 | 19 |
| Design assisted by testing | 14 | 20 |
| Durability | 15 | 21 |
| Fire resistance | 16 | 22 |
| Sustainable steel construction | — | 23 (new) |
| Fabrication and erection | 17 | 24 |
| Plate girders with corrugated web | — | Annex G (new) |
Width-to-thickness limits (Table 2)
Plastic / compact / semi-compact limits.
| Element | IS 800:2007 | IS 800:2026 | Change |
|---|---|---|---|
| Web, neutral axis at mid-depth (d/tw) | 84ε / 105ε / 126ε | 70ε / 80ε / 117ε | Tighter, compact −24 % |
| Web, axial compression (d/tw) | — / — / 42ε | 27ε / 33ε / 37ε | Tighter, new class 1 and 2 limits |
| Flange outstand, rolled (b/tf) | 9.4ε / 10.5ε / 15.7ε | 8.7ε / 9.7ε / 13.6ε | Tighter |
| Flange outstand, welded (b/tf) | 8.4ε / 9.4ε / 13.6ε | 8.7ε / 9.7ε / 13.6ε | Slightly looser |
| Angle, compression due to bending (b/t, d/t) | 9.4ε / 10.5ε / 15.7ε | 8.7ε / 9.7ε / 14.5ε | Tighter |
| Single angle, axial (b/t, d/t; (b+d)/t) | 15.7ε; 25ε | 14.5ε; 22.3ε | Tighter |
| Angle leg back-to-back (d/t) | 9.4ε / 10.5ε / 15.7ε | 8.7ε / 9.7ε / 14.5ε | Tighter |
| Circular hollow, bending (D/t) | 42ε² / 52ε² / 146ε² | 48ε² / 68ε² / 87ε² | Class 1, 2 looser; class 3 much tighter |
| Circular hollow, axial (D/t) | 88ε² | 87ε² | About the same |
What it means at fy 345 (ε ≈ 0.85):
| Member | d/tw or b/tf | Class in 2007 | Class in 2026 | Effect |
|---|---|---|---|---|
| Welded column or haunch web, bending | 68 to 89 | Compact | Semi-compact | Md from Ze, −8 to −15 % |
| Welded web, bending | 100 to 107 | Semi-compact | Slender | Effective section needed |
| ISHB 300 flange at fy 410 | 11.8 | Semi-compact | Slender (limit ≈ 10.6) | Effective section needed |
Lateral-torsional buckling (15.2.2, Tables 13 and 14)
| Item | IS 800:2007 | IS 800:2026 |
|---|---|---|
| αLT, welded I, tf ≤ 40 | 0.49 | 0.21 √(Zez/Zey) ≤ 0.64 |
| αLT, welded I, tf > 40 | 0.49 | 0.25 √(Zez/Zey) ≤ 0.76 |
| αLT, rolled I or H, h/bf > 1.2, tf ≤ 40 | 0.21 | 0.12 √(Zez/Zey) ≤ 0.34 |
| αLT, other rolled I or H | 0.21 | 0.16 √(Zez/Zey) ≤ 0.49 |
| αLT, other rolled shapes | 0.21 | 0.76 |
| Moment-gradient factor fm | — | 1.0 uniform; 1.25 − 0.1ψ − 0.15ψ² linear; 1.05 UDL |
| Moment cap, simply supported beams | 1.2 Ze fy/γm0 | 1.2 Ze fy/γm0 |
| Moment cap, continuous and frame members | 1.2 Ze fy/γm0 (simply supported rule) | 1.5 Ze fy/γm0 |
| Moment cap, cantilevers | 1.5 Ze fy/γm0 | 1.2 Ze fy/γm0 |
| Simplified compression-flange method | — | New (15.2.2.2) |
Effect on a typical welded PEB rafter (600 × 200 × 6 × 10, fy 345), against 2007:
| Unbraced length | Uniform moment (fm 1.0) | Linear gradient, ψ = 0 (fm 1.25) |
|---|---|---|
| 1.5 m | −3 % | +12 % |
| 3.0 m | −5 % | +6 % |
| 4.5 m | −4 % | 0 % |
| 6.0 m and more | −3 % to 0 % | −1 % to 0 % |
Setups that check welded or tapered members with the rolled-section factor of 0.21 will see up to about 20 % less buckling strength.
Combined axial force and bending (16.3.2.2, Table 18)
| Item | IS 800:2007 | IS 800:2026 | Members to re-check |
|---|---|---|---|
| Minor-axis factor, semi-compact and slender | 0.6 × base factor | 1.0 × base factor (+67 %) | End-wall columns, eave struts |
| Minor-axis factor, compact I sections | up to 1 + 0.8n | up to 1 + 1.4n | Biaxial purlins and girts |
| Members that cannot buckle laterally, tubes, boxes | Both equations as usual | First equation with a reduced factor on the second moment | Tube and box members |
In a 2D main frame the minor-axis moment is close to zero, so main frames change little here.
Column buckling curves (Table 10)
| Section | IS 800:2007 | IS 800:2026 | Effect |
|---|---|---|---|
| Rolled I and hot-rolled tubes, fy > 420 | a | a0 (α = 0.13) | Better, +6 to +10 % |
| Cold-formed hollow sections | b | c | −6 % at λ 0.6, −10 % at λ 1.0 |
| Rolled angles | c | b | Better |
| Channels, tees, monosymmetric | Flexural only | Torsional and flexural-torsional check added (14.1.2.2) | Can govern bracing and chords |
The imperfection factors (a 0.21, b 0.34, c 0.49, d 0.76) and the χ formula are unchanged.
Seismic design (Section 18)
| Item | IS 800:2007 | IS 800:2026 |
|---|---|---|
| Ordinary moment frame, R | From IS 1893 (steel OMRF 3) | 4.0 |
| Non-ductile frame, R | — | 1.5 |
| Frames by zone | Ordinary frames restricted in zones IV and V | Ordinary frames zone II only; zone III and above special or non-ductile |
| Single-storey industrial frames, height/span below 1.0, regular | Ductile detailing to frame type | May be non-ductile: R = 1.5, no ductility rules |
| Connections of non-ductile frames | — | Full member capacity, +50 % force in zone V |
Tapered PEB frames with slender webs cannot meet the section rules of a moment frame, so most PEB frames will take R = 1.5. In light sheds in low zones wind often still governs; in zones IV and V, and with mezzanines or cranes, seismic governs more often than before.
Second-order effects (11.7.1)
| Frame | λcr / λp | What to do |
|---|---|---|
| Clad, cladding stiffness ignored | 10 or more | First-order analysis |
| 4.6 to 10 | Amplify first-order effects (11.7.3) | |
| below 4.6 | Second-order analysis | |
| Unclad, or cladding stiffness counted | 20 or more | First-order analysis |
| 5.75 to 20 | Amplify | |
| below 5.75 | Second-order analysis |
Low-pitch portals with tall columns can have λcr between about 4 and 10 under full gravity load.
Connections and column bases
| Item | IS 800:2007 | IS 800:2026 |
|---|---|---|
| Bolt shear and bearing | Vdsb, Vdpb with kb | Unchanged |
| Bolt tension | 0.9 fub An, capped by shank yield | Unchanged |
| Fillet weld, simple check | fu/(√3 γmw) | Unchanged |
| Fillet weld, combined stress | √(fa² + 3q²) ≤ fu/(√3 γmw) | Printed as ≤ fu/γmw; confirm with BIS before using |
| Base plate bearing on concrete | 0.6 fck | min(0.3 fck √(A1/A2), 0.9 fck) |
| Anchor bolts | — | At least 4; 6 for slab bases carrying earthquake forces |
| Crane runways, relative rail displacement | 10 mm | 25 mm |
New and removed clauses
| Clause | Status | What it covers |
|---|---|---|
| 11.7.1 | Changed | λcr check now applies to elastic analysis |
| 14.1.2.2 | Added | Torsional and flexural-torsional buckling |
| 15.2.2, Tables 13 and 14 | New | Shape-dependent αLT, moment-gradient fm |
| 16.3.2.2, Table 18 | New | Class-based interaction factors |
| 18.13 | New | Single-storey industrial buildings, R = 1.5 |
| 23 | New | Sustainable steel construction |
| Annex G | New | Plate girders with corrugated web |
| 2007 Section 11 | Removed | Working stress design |
Who is affected
| Member or building | What changes | Rough effect |
|---|---|---|
| Welded columns and haunches, d/tw ≈ 68–89 at fy 345 | Web compact → semi-compact | Md −8 to −15 % |
| Struts with webs near 37–42ε | Stricter web limit in compression | Axial −2 to −4 % |
| Welded rafters, LTB governing | New αLT and fm | −5 to +13 % |
| End-wall columns, eave struts, biaxial purlins and girts | Larger minor-axis factor | Minor-axis term up to +67 % |
| Cold-formed tube struts and bracing | Curve b → c | −6 to −10 % |
| Single-storey industrial frames in seismic zones | R = 1.5 | About 2.7× an R = 4 design |
| Tall, low-pitch portals | λcr check | Amplification or second-order |
| Column bases on slabs | Lower bearing, more anchor bolts | Larger plates |
Checklist while your software checks to IS 800:2007
Most design software, STAAD.Pro included, still checks members to IS 800:2007 at the time of writing.
| Check | What to do by hand |
|---|---|
| Web class | List welded webs with d/tw between the old and new limits (about 60 to 107 at fy 345) and re-check them as semi-compact or slender |
| LTB | Re-check welded rafters with the new αLT and fm |
| Seismic | Generate loads with R = 1.5 for single-storey industrial frames; design connections for full member capacity |
| Second order | Compute λcr for each frame; amplify or run P-delta below 10 (clad) or 20 (unclad) |
| Minor-axis members | Re-check end-wall columns, eave struts, purlins and girts |
| Cold-formed tubes | Use curve c |
| Base plates | Re-check bearing and the anchor bolt minimum |
| Design basis | Write the edition into the design basis and the drawing notes |
Ganithva checks steel members to IS 800:2026 as well as IS 800:2007: choose the edition on the PEB card, or ask for it in chat. IS 800:2007 stays the default.
Frequently asked questions
What is IS 800:2026?
IS 800:2026 is the Fourth Revision of IS 800, the Indian Standard code of practice for general construction in steel, published by the Bureau of Indian Standards in October 2026. It replaces IS 800:2007 and covers limit state design of steel members, connections, seismic design, fatigue, fire and fabrication.
What are the main changes in IS 800:2026 compared with IS 800:2007?
Tighter width-to-thickness limits for webs, a shape-dependent imperfection factor and a moment-gradient factor for lateral-torsional buckling, class-based interaction factors for combined forces, cold-formed tubes moved to buckling curve c, R = 1.5 for non-ductile industrial frames, a λcr check for second-order effects, a lower concrete bearing limit under base plates, and working stress design withdrawn.
Is working stress design allowed in IS 800:2026?
No. IS 800:2026 withdraws working stress design (Section 11 of the 2007 edition). Design is by the limit state method only.
Do I have to design to IS 800:2026 from now on?
That depends on your contract and on the transition period BIS sets. Many design bases and client specifications still name IS 800:2007, and a job is designed to the edition its design basis names. Check the design basis of each new job, and agree the edition with the client before the first calculation.
Which PEB members are hit hardest by IS 800:2026?
Welded columns and haunches with slender-ish webs, because the web limits in bending are tighter; semi-compact and slender members with minor-axis moment, such as end-wall columns, eave struts and biaxially loaded purlins and girts; cold-formed tube bracing; and, in seismic zones, the whole frame, because single-storey industrial frames take R = 1.5.
Where can I get the IS 800:2026 code?
From the Bureau of Indian Standards (BIS), through its official standards portal. Use a licensed copy: unofficial PDF copies can be incomplete or carry the wrong amendments, and the code is protected by BIS copyright.
Does IS 800:2026 add rules for tapered members?
No. As in the 2007 edition, tapered members have no dedicated provisions. Check the section at enough stations along the member, with the classification, capacity and buckling rules applied to each station.