1.Why the choice matters

Indian PEB work is designed to two steel codes. IS 800:2007 is the national code and is required by most domestic clients, government work and many consultants. AISC 360 (the American specification, in its 2005, 2010 or 2016 edition) is common for export projects, for multinational clients, and for consultants who already work to American codes.

IS 800 now has a new edition, IS 800:2026 (Fourth Revision, October 2026). This guide compares IS 800:2007 with AISC 360; for what the 2026 edition changes, see IS 800:2026 vs IS 800:2007 comparison tables.

The codes agree on the physics but differ in detail, and PEB frames sit exactly where those details matter: slender built-up webs, long unbraced flanges and combined axial force and bending in tapered members. The design basis must name one code and use it consistently.

2.Design philosophy and safety factors

IS 800:2007 uses limit state design. Loads are multiplied by partial safety factors, and resistances are divided by partial safety factors for material: γm0 = 1.10 for resistance governed by yielding and buckling, and γm1 = 1.25 for resistance governed by ultimate stress (for example net section rupture). The code also keeps a working stress chapter, but limit state design is the normal choice.

AISC 360 offers two equivalent formats on the same nominal strengths. In LRFD the nominal strength is multiplied by a resistance factor φ (0.90 for flexure, compression and tension yielding; 0.75 for tension rupture). In ASD it is divided by a safety factor Ω (1.67 and 2.00 for the same cases). LRFD is the closer match to IS 800.

3.Load combinations

Under IS 800:2007, typical strength combinations for a PEB are:

  • 1.5 (DL + LL)
  • 1.2 (DL + LL + WL) or 1.2 (DL + LL + EL)
  • 1.5 (DL + WL), and 0.9 DL + 1.5 WL where dead load resists the wind (uplift and overturning)

Serviceability checks use unfactored or reduced factors on the same loads.

AISC 360 takes its combinations from the American load standard. The trap for Indian projects is wind. IS 875 (Part 3) gives wind at a 50-year return period, intended to be factored by about 1.5 for strength. Recent editions of the American load standard give wind at a much longer return period, already at strength level, with a load factor of 1.0. If you take IS 875 wind and use 1.0 W combinations, you under-design; if you take American wind at strength level and apply 1.5, you over-design. State in the design basis which loads are used and which factors go with them. The IS 875 Part 3 wind load guide explains the Indian wind calculation.

4.Section classification

Built-up PEB sections often have thin webs and wide flanges, so classification matters a great deal.

IS 800 has four classes: plastic, compact, semi-compact and slender. Limits are expressed in terms of ε = √(250/fy), with separate limits for rolled and welded flanges. Welded flange outstands have tighter limits than rolled ones. For a web in pure bending the plastic, compact and semi-compact limits are 84ε, 105ε and 126ε on d/tw; deeper PEB webs often exceed these and are slender.

AISC 360 uses compact, noncompact and slender, with limits in terms of √(E/Fy). For a web in flexure the compact limit is 3.76√(E/Fy) and the noncompact limit 5.70√(E/Fy). For flanges of built-up sections the noncompact limit includes a factor kc that depends on the web slenderness.

In a tapered member the web slenderness changes along the length, so the class can change from one end to the other. Check classification at every check point, not once per member.

5.Shear, buckling and interaction

Shear

IS 800 requires a shear buckling check when an unstiffened web has d/tw greater than 67ε, and allows tension field action in stiffened webs. AISC 360 Chapter G covers shear yielding and buckling; the 2016 edition revised the shear buckling and tension field provisions.

Lateral-torsional buckling

IS 800 calculates the elastic critical moment and applies a buckling curve with an imperfection factor αLT, which is 0.21 for rolled sections and 0.49 for welded sections, so built-up PEB members get the more severe curve. AISC 360 Chapter F uses limiting lengths Lp and Lr, with a moment gradient factor Cb that rewards non-uniform moment. In both codes the unbraced length is the biggest lever, which is why flange brace positions matter so much in PEB frames.

Combined axial force and bending

IS 800 checks section strength and then overall member buckling with interaction factors (ky, kz, kLT). AISC 360 Chapter H uses a bilinear equation: for Pr/Pc ≥ 0.2, Pr/Pc + 8/9 (Mrx/Mcx + Mry/Mcy) ≤ 1.0, and for smaller axial force, Pr/(2Pc) + (Mrx/Mcx + Mry/Mcy) ≤ 1.0. PEB columns usually have modest axial load and large moment, so the bending terms dominate in both.

6.Frame stability and tapered members

AISC 360 (from 2005, and as the main method from 2010) uses the direct analysis method: a second-order analysis with notional loads and reduced stiffness, after which members are checked with their actual lengths. The older effective length method remains as an alternative. IS 800 requires notional horizontal forces of 0.5% of factored gravity load and consideration of second-order effects where sway is significant.

Neither code has a full chapter for web-tapered members today. Under AISC 360, AISC Design Guide 25 gives a detailed procedure for frames with web-tapered members. Under IS 800, engineers check the general provisions at many sections along each member, using the properties at each point. Whichever code you use, record the method in the design basis. Our PEB optimization guide covers how these checks drive section sizes.

7.Which code to use

  • Use IS 800:2007 when the client, the consultant, the approving authority or the tender asks for Indian codes, which is the default for domestic work.
  • Use AISC 360 when the specification calls for it, often for export or for clients with global standards, and keep the load combinations consistent with the wind and seismic loads you use.
  • Do not mix checks from both codes in one design, and do not move a design from one code to the other without re-running every check.

Design software should let you run the same frame to either code and compare the results. If you model in STAAD.Pro, the PEB design in STAAD.Pro guide covers the workflow.

8.FAQ

Is IS 800:2007 the same as AISC 360 LRFD?

No. Both are limit state (factored load) methods, but they differ in how resistance is reduced (partial material factors in IS 800, resistance factors in AISC 360), in section classification limits, in buckling curves and in the interaction equations. The same frame can show different utilisations under each.

Can I use IS 875 wind loads with AISC 360?

Yes, many Indian projects do, but the load factors must be consistent with the wind loads. IS 875 wind loads are at a 50-year return period and are meant to be multiplied by a load factor of about 1.5. Recent American load standards give wind at a much longer return period with a factor of 1.0, so applying those combinations to IS 875 wind would under-design the frame.

Which code gives a lighter PEB frame?

Neither code is lighter in general. The result depends on which checks govern: classification of slender webs, lateral-torsional buckling, interaction or deflection. The reliable way to know is to design the same frame to both codes and compare.

Does IS 800 cover tapered members?

IS 800:2007 has no separate chapter for web-tapered members. In practice tapered members are checked at many sections along their length using the general provisions, with care over effective lengths and buckling. AISC Design Guide 25 gives detailed guidance for web-tapered frames designed to AISC 360.

Which AISC 360 edition should I use?

Use the edition required by the contract or the client. 2005, 2010 and 2016 are all still specified. The editions share the same overall structure, but stability analysis and shear provisions were revised along the way, so the design basis should state the edition.

Ganithva checks PEB members to IS 800:2007, IS 800:2026 and AISC 360 (2005, 2010 and 2016) in its own analysis and design-check engine, and the engineer approves every change. See PEB design software and PEB optimization, or book a walkthrough.

Automate. Engineer. Optimize.