STAAD.PRO AND AI

STAAD.Pro LOAD COMB vs REPEAT LOAD: which one your PEB model needs

Both commands give you a load combination. One adds up answers, the other builds a new problem and solves it. In a linear model they agree; once the analysis is non-linear, they do not.

16 NOVEMBER 2026 · 6 MIN READ

Every PEB model in STAAD.Pro ends up with a long list of combinations: dead plus live, dead plus wind in several directions and with internal pressure and suction, dead plus seismic, collateral load, crane cases and more. There are two ways to write those combinations in the input file, LOAD COMB and REPEAT LOAD. They look similar in the editor and they often give identical numbers. The cases where they do not are exactly the cases a PEB designer cares about.

What LOAD COMB does

LOAD COMB works on results. The program first analyses each primary load case on its own: dead, live, wind, and so on. After the analysis it takes the displacements, member forces and reactions of those cases, multiplies each by the factor you gave, and adds them.

This is linear superposition. It is fast, because nothing is solved again, and it is exactly right as long as the structure behaves linearly: stiffness does not depend on the load, and the response to two loads together is the sum of the responses to each.

What REPEAT LOAD does

REPEAT LOAD works on loads. It creates a new primary load case whose loading is the factored sum of the loads in the cases you list. The program then analyses that new case like any other primary case.

For a linear analysis, analysing the summed loads and summing the results give the same answer, so the two commands agree. The difference appears as soon as the analysis is not linear.

Where the two give different answers

P-Delta (second-order) analysis

In a PDELTA analysis the program accounts for the extra moments caused by axial load acting through the lateral displacement of the frame. That effect depends on how much axial load is present at the same time as the sway.

With LOAD COMB, each primary case is analysed separately. The wind case on its own has little axial load in the columns, so its second-order amplification is small. The dead case on its own has almost no sway. Adding the two afterwards misses the interaction: the full gravity load acting through the wind sway. The combination can look safer than it is.

With REPEAT LOAD, the gravity and wind loads are applied together and the second-order analysis sees both at once. That is the result you want to design from.

Tension-only and compression-only members

Rod and cable bracing in PEB side walls and roofs is often modelled as tension-only. Whether a given brace is active depends on the direction of the load. Each primary case is solved with its own set of active braces, so adding them later with LOAD COMB can combine results from two different structural systems. A combined case built with REPEAT LOAD is solved once, with the braces that are actually in tension under that combination.

Other non-linear features

The same reasoning applies to any feature where the stiffness depends on the load, such as supports that act in one direction only. If the model has any of these, check how each combination is formed before you trust it.

Quick comparison

Aspect LOAD COMB REPEAT LOAD
Combines Results of analysed cases Loads, then analyses
Analysis cost Very low One extra solution per case
Linear analysis Correct Correct (same result)
P-Delta analysis Misses load interaction Captures it
Tension-only bracing Can mix brace states Consistent brace state
Typical use Linear models, serviceability, reporting Second-order design cases, non-linear members

Practical advice for PEB models

  1. Decide the analysis type first. If the frames will be designed with second-order effects, every strength combination that feeds the design should be a REPEAT LOAD case analysed with PDELTA. If the office designs from a first-order analysis and handles sway effects through the code’s amplification or effective-length approach, LOAD COMB is consistent with that choice. Mixing the two approaches is where errors come from.

  2. Write the primary cases cleanly. Keep dead, collateral, live, each wind case, each seismic case and each crane case as separate primary cases with clear titles. Both commands depend on this, and it makes the input file readable for the checker.

  3. Keep the factors in one place. Partial safety factors for IS 800:2007 limit state design and for AISC 360 differ, so write them in one table in your design basis and generate the combinations from that table. Typing factors by hand into dozens of cases is the most common source of a wrong combination. Our guide to IS 800 vs AISC 360 for PEB covers the differences in approach.

  4. Check the load case order. A REPEAT LOAD case can only refer to load cases that are already defined above it in the input. Put all primary cases first, then the repeat cases.

  5. Point the design at the right cases. If both kinds of combination exist in the model, make sure the steel design reads the strength cases and not the serviceability cases. The load list before the design commands controls this.

  6. Use a sanity check. Run one combination both ways in a copy of the model. In a linear run they should agree to rounding. In a P-Delta run the REPEAT LOAD version should usually show larger sway moments in the columns. If it does not, look at the axial load and stiffness before moving on.

  7. Watch serviceability separately. Deflection and drift checks are normally done with unfactored or serviceability combinations. These are often fine as LOAD COMB cases, but they should use the same analysis type the office has chosen for the frame.

Common mistakes

  • Turning on PDELTA but leaving all strength combinations as LOAD COMB, which gives the impression of a second-order design without its substance.
  • Combining wind cases with the wrong internal pressure sign because the primary cases were not titled clearly. See our guide to IS 875 Part 3 wind load for PEB for the cases you normally need.
  • Forgetting that self-weight sits inside the dead load case, so applying it again as a separate factored item counts it twice.
  • Copying a combination block from an older job built for a different code or a different set of primary cases.

Where automation helps

Combination blocks are a good candidate for generation rather than typing: the rules are fixed, the number of cases is large and a single wrong factor is hard to spot. Ganithva can open a STAAD.Pro model and write or correct combination blocks from a plain-language request, with a checkpoint before each change so the engineer can review and revert. For the wider picture, see STAAD.Pro automation and our post on what to automate in STAAD.Pro first.

Whichever command you use, the engineer of record decides the analysis method and checks the combinations. The command only does what the input tells it to.

Frequently asked questions

Is LOAD COMB wrong for a P-Delta analysis?

It is not wrong as a command, but it gives the wrong kind of answer. LOAD COMB adds the results of primary cases that were each analysed on their own, so the second-order effect of the full combined gravity load acting with the lateral load is never computed. For P-Delta, combine the loads first with REPEAT LOAD and let the program analyse that combined case.

Does REPEAT LOAD make the analysis slower?

Yes. Every REPEAT LOAD case is a new primary load case that the program has to solve, while a LOAD COMB is only a sum of results after the solution. For a typical single-storey PEB the extra time is usually small, but in large models with many combinations it adds up.

Can I mix LOAD COMB and REPEAT LOAD in one model?

Yes, and many offices do. A common pattern is REPEAT LOAD for the combinations that will be designed with second-order effects and LOAD COMB for serviceability or reporting cases that stay linear. Keep the numbering clear so the design and the reports read the right cases.

Automate. Engineer. Optimize.