PEB BASICS

PEB roof slope selection: how to choose between 1:10, 1:20 and others

Roof slope looks like an architectural detail, but it changes drainage, sheeting choice, frame weight and wind loads. Here is how to pick it on purpose rather than by habit.

16 NOVEMBER 2026 · 7 MIN READ

Ask ten PEB designers why a roof is at 1:10 and several will say it is what they always use. That is not a bad starting point, but the slope affects more of the building than it appears to. It decides how fast rain leaves the roof, which sheeting systems are allowed, how the main frame carries load, how much wind suction the roof sees, and how tall the building ends up.

Slopes and angles

Roof slopes in PEB are normally stated as a ratio of rise to horizontal run.

Slope Angle (approx.) Rise over a 15 m half-span
1:20 2.9° 0.75 m
1:12 4.8° 1.25 m
1:10 5.7° 1.5 m
1:8 7.1° 1.875 m
1:6 9.5° 2.5 m

The last column shows why slope matters on wide buildings: for a 30 m clear span, moving from 1:20 to 1:10 doubles the height of the ridge above the eave. On a 60 m span the difference is larger still.

Drainage and sheeting

The first job of a roof is to shed water. Rain in India arrives in short, heavy bursts during the monsoon, and a roof that cannot clear it quickly leaks at laps and fasteners.

  • Through-fastened profiled sheets are screwed through the sheet into the purlin and lapped at the ends. Water must run past every end lap and fastener. Each sheet manufacturer states a minimum slope for its profile, which often depends on whether there are end laps and how long the sheet run is. Below that slope, water can back up through the laps.
  • Standing seam roofs have concealed clips and raised, folded seams, with few or no exposed fasteners. They are made for low slopes and long runs, which is why they pair well with 1:20 roofs on wide buildings.
  • Long sheet runs need more slope, or a better sheet, because more water collects towards the eave.

Always confirm the minimum slope with the actual sheet supplier for the actual profile. Then add a margin, because the frame will deflect and the installed slope will be less than the drawn slope at mid-span.

Gutters are part of the same decision. A flatter roof sends water to the eaves more slowly but still delivers the same total volume; the eave gutters and downpipes must be sized for the design rainfall. A multi-gable roof adds valley gutters, which need generous sizing, overflows and regular cleaning.

Effect on the main frame

The rafter of a portal frame carries load partly by bending and partly, as the slope increases, by arch action that pushes outward at the eaves. At typical PEB slopes the frame still works mainly in bending, but slope still changes the result:

  • Steeper slopes give the rafter a little more arch action under gravity load, can reduce mid-span deflection, and increase the outward thrust at the knee.
  • Steeper slopes also add roof area, sheeting, purlin length and wall height at the gables. The gable walls grow and so does the wind load on them.
  • Flatter slopes keep the building lower and the roof area smaller, but the rafter works almost as a beam, and deflection checks become more important.

There is no single slope that is lightest for every building. Span, eave height, loads and deflection limits all interact. If tonnage matters, check two or three slopes for the actual building rather than assuming. Our guide to tapered frame design covers the other variables that move frame weight.

Wind uplift

Under IS 875 Part 3, the external pressure coefficients on a pitched roof depend on the roof angle and the ratio of height to width. For the low slopes used in PEB, the roof is generally in suction for most wind directions, with higher local suction at eaves, ridge and corners. Internal pressure from openings can add to it.

Uplift affects:

  • purlins and fasteners, where suction pulls the sheet off the purlin and puts the purlin’s free flange in compression,
  • flange bracing on rafters, because uplift reverses the bending and compresses the inner flange,
  • anchor bolts, because the frame dead load may not be enough to hold the columns down,
  • the sheeting itself, through fastener pull-through.

In coastal and cyclone-prone regions, uplift often governs more of the design than gravity. The slope is not a way to avoid wind load, but it does change the coefficients, so the wind calculation must match the slope that will be built. See IS 875 Part 3 wind load for PEB for the full method.

Imposed load, ponding and snow

Roof imposed load under IS 875 Part 2 depends on whether the roof has access and on its slope, with lower values for steeper roofs beyond a certain angle. Use the value for the actual slope and access condition.

Ponding is the risk on flat roofs. If a roof is very flat and the rafter or purlins deflect, water collects at mid-span, adds load, increases deflection and collects more water. To avoid it:

  • keep the slope comfortably above the sheet minimum,
  • limit deflection so that the deflected roof still drains,
  • check purlins and rafters near blocked gutters or parapets, where water can stand.

Snow applies in hilly regions of north India. IS 875 Part 4 sets snow loads, including drifting against parapets, higher roofs and valleys. Steeper slopes help snow slide off, but they can also load gutters and lower roofs below. Low-slope multi-gable roofs in snow areas need special care at the valleys.

Solar panels and services

Many new industrial roofs carry rooftop solar. Panel mounting is simplest on lower slopes, where rails can follow the roof or be tilted on short frames. The added dead load and the wind forces on the panels, which can be significant at edges, must be included in the purlin and frame design. Discuss solar with the owner before the slope is fixed, not after the steel is ordered.

A simple way to decide

  1. Fix the sheeting system with the owner: through-fastened or standing seam.
  2. Get the supplier’s minimum slope for that profile and sheet run, and add margin for deflection.
  3. Check the ridge height that results. If it clashes with planning rules, crane clearance or architectural intent, revisit the span or the frame type.
  4. Run the wind load for that slope and confirm uplift on purlins, fasteners and anchors.
  5. Compare frame tonnage for one or two alternative slopes if the building is large.
  6. Size gutters and downpipes for the chosen slope and roof layout.

A roof slope chosen this way will drain, will not leak at laps, and will not leave tonnage on the table.

Frequently asked questions

What is the most common roof slope for PEB buildings in India?

Slopes of 1:10 and 1:20 are both widely used. 1:10 gives better drainage and suits through-fastened sheeting, while flatter slopes like 1:20 are often used with standing seam roofs and very wide buildings where a steep slope would push the ridge too high.

What angle is a 1:10 roof slope?

A 1:10 slope rises 1 unit for every 10 units horizontally, which is about 5.7 degrees. A 1:20 slope is about 2.9 degrees and a 1:12 slope is about 4.8 degrees.

Does a steeper roof make the PEB frame lighter?

Not always. A steeper rafter gains some arch action under gravity load, which can reduce bending, but it also adds roof area, wall height and wind load. The lightest slope depends on span, loads and eave height, so it is best found by checking the options for the actual building.

Is wind uplift worse on a low-slope roof?

Low-slope roofs generally see suction over most of the roof under IS 875 Part 3, with higher local suction near the eaves, ridge and corners. Uplift often governs purlins, fasteners, flange bracing and anchor bolts in high-wind areas.