# How to read STAAD.Pro steel design output for a PEB

A column of PASS and a ratio below 1.0 is not the end of the check. The ratio is only as good as the lengths, parameters and load cases behind it.

16 NOVEMBER 2026 · 7 MIN READ

**Key points**

- The ratio in STAAD.Pro steel design output is the largest utilisation among all checks and all load cases in the design list; a ratio above the permissible value, normally 1.0, is reported as a failure.
- The critical condition in STAAD.Pro steel design output shows why a member is at its ratio, such as compression buckling, combined axial and bending, shear or lateral torsional buckling, and points to what to change.
- In STAAD.Pro, LY and LZ are the flexural buckling lengths and UNL is the unbraced compression flange length for lateral torsional buckling; each defaults to the analytical member length if not assigned.
- The most common false pass in a STAAD.Pro PEB model is a split rafter or column checked with default segment lengths instead of the real distance between flange braces.
- Deflection, drift, connection design and web crippling at concentrated loads may not be part of a STAAD.Pro steel design run, so they need separate checks on every PEB job.

After the analysis, a `CHECK CODE` or `SELECT` command makes STAAD.Pro check each steel member against the chosen code, such as IS 800:2007 or AISC 360. The output lists every member with a result, a ratio and the condition that governed. For a PEB with tapered frames, purlins, girts and bracing, that is a long table. Reading it well means knowing what each column tells you, and what it does not.

## What the design output contains

The exact layout depends on the code and the program version, but the summary for each member usually shows:

| Item | What it tells you |

| Member number and section | Which member and which profile was checked |

| Result | PASS or FAIL against the permissible ratio |

| Critical condition | The check that governed, often with the code clause |

| Ratio | Utilisation for the governing check |

| Load case | The combination that produced the governing ratio |

| Location | Distance along the member where it governed |

A detailed output option prints the intermediate values for each member: section class, resistances, slenderness, effective lengths and the interaction checks. For a PEB, ask for the detailed output on at least one column and one rafter of each frame type and read it once from top to bottom.

## Reading the ratio

The ratio is the **largest** utilisation among all checks and all load cases in the design list. That means:

- A ratio of 0.95 tells you the member is close to its limit in **one** check. Other checks may be much lower.

- A low ratio across a whole frame can mean the section is heavy, or that the members were checked against the wrong loads.

- Changing a section to fix one failure can move the governing check somewhere else. Re-run and read again.

The permissible ratio is normally 1.0. Some offices set a lower limit as a margin for items that the model does not capture. If you change it, record it in the design basis.

## Critical condition and governing clause

The critical condition tells you **why** the member is at its ratio: axial tension, axial compression buckling, bending, shear, combined axial and bending, or lateral torsional buckling. Many code implementations print the clause reference as well.

Use it to decide what to change:

- **Combined axial and bending or buckling** in columns usually responds to depth, flange size or a shorter buckling length through extra bracing.

- **Lateral torsional buckling** in rafters often responds better to an extra flange brace than to a heavier section.

- **Shear** near the knee points to web thickness or a stiffener.

- **Slenderness limits** on bracing and secondary members point to a different profile, not more strength.

Do not assume what governs. Read it. For differences in how IS 800 and AISC 360 frame these checks, see our guide to [IS 800 vs AISC 360 for PEB](https://ganithva.com/guides/is-800-vs-aisc-360-peb).

## Unbraced and effective lengths: UNL, LY and LZ

These parameters decide the buckling checks, and they are where most design errors in PEB models hide.

- **`LY` and `LZ`** are the lengths for flexural buckling about the local y and z axes. Effective length factors can be applied on top.

- **`UNL`** is the unbraced length of the compression flange for lateral torsional buckling.

- If you do not assign them, each one **defaults to the length of the analytical member**.

That default is reasonable for a single member between two braced points. It is often wrong in a PEB model:

- **Split rafters and columns.** A rafter is usually divided into segments at taper changes and splices. Each segment is a separate analytical member, so the default length is the segment length, not the distance between flange braces. The member can show PASS when the real unbraced length is two or three segments long.

- **Inside and outside flange.** Purlins restrain the top flange of the rafter. Under gravity, the bottom flange near the knee is in compression and is braced only where flange braces are provided. Under wind uplift, the compression flange can change. `UNL` should reflect the flange that is in compression for the governing case, which may need separate checks.

- **Columns.** Girts restrain the outer flange. The inner flange of a column is braced only by flange braces. The out-of-plane buckling length depends on those braces and on the side wall bracing.

- **In-plane length.** For a portal frame, the in-plane buckling length of a column depends on the frame behaviour and the analysis method, not just the member length. Decide it from the design basis and the code, not from the default.

Assign these lengths deliberately for each member group and keep a short table in the design notes showing how each value was chosen.

## Common causes of failures

- **Real overstress.** Section too light for the load. Change the section or the bracing.

- **Wrong effective length factor** or a buckling length that is too long, perhaps copied from another member group.

- **Load cases out of scope.** Serviceability or unfactored cases included in the design list produce misleading results; ratios can also come from primary cases that were never meant to be designed.

- **Section classification.** Thin webs in tapered plate members can be slender. Check how the program and the code treat slender sections and read any warning about classification.

- **Units or property errors** in the section definition.

## Common causes of false passes

A false pass is more dangerous than a failure, because nobody looks at it twice.

- **Default lengths on split members**, as above.

- **Design run on the wrong load list**, missing the governing wind or crane combination.

- **Combinations formed with `LOAD COMB` in a P-Delta model**, so second-order effects are understated. See our post on [LOAD COMB vs REPEAT LOAD](https://ganithva.com/blog/staad-pro-load-comb-vs-repeat-load).

- **Members excluded from design** by mistake, so they never appear in the output.

- **Checks the code requires but the run did not include**, such as deflection, drift, connection design, web crippling at concentrated loads or local checks at the knee. These need separate attention.

## A reading routine for every PEB job

- Confirm every designed member appears in the output.

- Sort by ratio. Read the top results first, then the lowest, which can point to oversized or wrongly loaded members.

- For each frame type, open the detailed output of the column and the rafter and confirm the lengths used.

- Note the governing load case for each frame. If one combination governs everywhere, check it was built correctly.

- Check deflection and drift separately against the limits in the design basis.

## Using the output to optimize

Once the lengths and loads are right, the ratios become a guide to steel weight: members well below their limit are candidates for a lighter section or a shallower taper. Our guide to [tapered frame design](https://ganithva.com/guides/peb-optimization) covers how to do that without creating new failures. Ganithva runs IS 800:2007 and AISC 360 checks with its own analysis and design-check engine, and proposes optimized tapered sections for the engineer to review. The engineer of record still decides and signs.

## Frequently asked questions

### What does the ratio in STAAD.Pro design output mean?

It is the governing utilisation of the member: the largest ratio of design action to design resistance among all the checks the program carried out, for all the load cases in the design list. A ratio above the permissible value, normally 1.0, is reported as a failure.

### What is the difference between UNL and LY or LZ?

LY and LZ are the lengths used for flexural buckling about the member's local y and z axes, together with any effective length factors. UNL is the unbraced length of the compression flange used for lateral torsional buckling in bending. They are separate inputs and each defaults to the member length if you do not set it.

### Why does a member pass in STAAD.Pro but fail in a hand check?

The most common reason is a design length that is too short. If a rafter is split into several analytical members and no UNL, LY or LZ is given, each segment is checked with its own short length instead of the real distance between braces. Other causes include design run on the wrong load cases or a section property that does not match the drawing.